Baird MWA Generator

Controlled MWA energy for efficient ablation workflows

The Baird microwave ablation (MWA) generator combines adjustable microwave output, integrated cooling, and real-time temperature monitoring.

Baird MWA generator (BD-GT)

2450 MHz

Microwave energy

0–70 W

Adjustable output

3 modes

Foot · Continuous · Pulse

Built-in

Cooling circulation

Real-time

Temperature monitoring

The Microwave Ablation System (BD-GT) is FDA-cleared for the coagulation (ablation) of soft tissue and supports physician-directed control from setup through energy delivery.

Energy delivery

No grounding pad required

The Baird MWA system delivers 2450 MHz microwave energy through a Baird MWA needle to generate heat within tissue. Unlike monopolar RF ablation, it does not require a grounding pad to complete an electrical circuit through the patient.

Close-up of the BD-GT control surface and front panel

Output modes

Three output modes

Foot mode

Foot-switch activation supports hands-free microwave output when the clinician's hands are occupied at the sterile field or imaging interface.

Activation
External foot switch
Time setting
1–99 s
Control
Physician-directed

Modes provide additional operating options and do not change the device’s intended use. All settings are physician-selected according to the IFU.

See the system in your own workflow
BD-GT operating display showing power, time, mode, pump status, and temperature values

Interface visibility

Stay informed. Stay in control.

Power, time, operating mode, temperature, and cooling status stay visible in one real-time view. Visual and audible alerts indicate abnormal conditions, helping you stay focused and in control throughout the procedure.

Cooling & monitoring

Built-in cooling with temperature safeguards

Cooling is built into the system’s energy-delivery sequence. A peristaltic pump circulates water or saline through Baird MWA needles, and microwave output is enabled only after cooling is active. Real-time temperature monitoring and over-temperature protection work together to support controlled MWA delivery throughout treatment.

Close-up of the BD-GT integrated peristaltic cooling pump
Built-in peristaltic cooling pump
Clinician adjusting the Baird Medical BD-GT microwave ablation system during use

Bring controlled MWA into your workflow

Talk with the Baird Medical team about system fit, training, implementation, and ongoing support for your MWA program.

Indications & Safety

Rx only. The Microwave Ablation System (BD-GT) is indicated for coagulation (ablation) of soft tissue. Not intended for cardiac use. Contraindicated in patients with massive bleeding tendency; not recommended for pregnant women; use caution in patients with severe coagulation dysfunction. Potential risks and complications include pain, bleeding or hematoma, swelling, thyroid-function changes, voice changes, and injury to nearby structures. Refer to the Safety Information and the Instructions for Use.

FDA 510(k) K232240 · Class II